Immediate Loading of Onepiece Root Form Implant: A Case Report with 3 Years’ Follow-up

Shilpa Shivanand, Navnita Singh, Shivaprasad Bilichodmath

Citation Information : Shivanand S, Singh N, Bilichodmath S. Immediate Loading of Onepiece Root Form Implant: A Case Report with 3 Years’ Follow-up. J Health Sci Res 2016; 7 (1):16-18.

DOI: 10.5005/jp-journals-10042-1027

Published Online: 01-12-2016

Copyright Statement:  Copyright © 2016; The Author(s).


Abstract

Aim

The aim of this case report was to evaluate the clinical performance of a onepiece implant in a partially edentulous anterior mandible.

Introduction

Osseointegration being an accepted and well-documented concept, attention is nowdirected toward simplification of the mechanical design of implants and toward achieving biomechanical success.

Case report

This case report demonstrates the immediate loading of one piece root form implant in esthetically concern patient. Patient came to the clinic with the chief complain of missing lower front teeth and wanted replacement of the same.

Conclusion

A single stage, one piece implant placement with immediate loading provides a good soft tissue healing and minimal postoperative discomfort to the patient.

Clinical significance

One piece root form implants is a reliable treatment protocol in esthetically concerned patients.

How to cite this article

Bilichodmath S, Shivanand S, Singh N. Immediate Loading of Onepiece Root Form Implant: A Case Report with 3 Years’ Follow-up. J Health Sci Res 2016;7(1):16-18.


PDF Share
  1. Simplifying the implant treatment for an unrestorable premolar with a one-piece implant: a clinical report. J Prosthet Dent 2008;100:81-85.
  2. Design features that may influence bacterial Plaque retention: a retrospective analysis of failed implants. Quintessence Int 2000;31:249-256.
  3. Marginal Fit and Microgaps of Implant-abutment Interface with Internal Antirotation Configuration. Dent Mat J 2008;27(1):29-34.
  4. Clinical experience with one-stage nonsubmerged dental implants. Adv Dent Res 1999;13:153-161.
  5. Clinical performance and radiographic evaluation of a novel single-piece implant in a private practice over a mean of seventeen months. J Prosthet Dent 2007;97:S69-S78.
  6. Persistent acute inflammation at the implant abutment interface. J Dent Res 2003; 82:232-237.
  7. Parel, Sterling R. Schow. Early Clinical Experience with a New One-Piece Implant System in Single Tooth Sites. J Oral Maxillofac Surg 2005; 63(9 S2):2-10.
  8. One piece root form implants: a return to simplicity. J. Oral implantol 2005;2:77-84.
  9. Retrospective Multicenter Analysis of Immediate Provisionalization Using One- Piece Narrow-Diameter (3.0-mm) Implants. Int J Oral Maxillofac Implants 2011;26: 163-168.
  10. Effect of flapless surgery on pain experienced in implant placement using an imageguided System. Int J Oral Maxillofac Implants 2006;21: 298-304.
  11. The Effect of Flapless Surgery on SingleTooth Implants in the Esthetic Zone: a Randomized Clinical Trial J Periodont 2013.
  12. Survival rate of one piece dental implants placed with flapless or flap protocol - A Randomized, controlled study; 12 months results. Int J Periodont Dent 2011;31:591-601.
  13. Singlestage, immediate loading, and flapless surgery J Oral Implantol 2000;26:193-98.
  14. Immediate Versus OneStage Restoration of Small Diameter Implants for a Single Missing Maxillary Lateral Incisor: a 3 years Randomized Clinical Trial J Periodontol 2009;80:139-398.